LM961: Power Consumption Reference
Tests were conducted using Firmware SPPC_0109. Further testing is planned including more parameters (as of September 2018).
LM961
- Module as Slave/Master, DCOV=ON = 26mA.
- Module as Slave/Master, DCOV=OFF=8mA.
- Module connected to remote device (Master/Slave) = Connected, no data transmission = 11mA.
- Module connected to remote device (Master/Slave) = Connected, data transmission Transmit/Receive = 16mA. This current may vary on the distance between two devices.
We observe a rise in the current while establishing SPP connection where current rises to 30 mA, after the connection is established the current is 11mA.
- Module SPP Role Master/Slave, DCOV=ON, ENBGAP=ON Current=26mA
- Module SPP Role Master/Slave, DCOV=OFF, ENBGAP=ON Current=8mA
- Module SPP Role Master/Slave, DCOV=OFF, ENBGAP=ON, LE connected, Current=9mA